The input module is used to receive normally open or normally closed switch signals input by the fire linkage equipment, and transmit linkage information back to the fire alarm control panel (linkage). Voltage:Loop : DC24V(16V~28V)
Current:Standby...
It is mainly used to connect fire-protection linkage equipment that needs to be controlled by fire alarm control panel, such as smoke exhaust valve, air supply valve, fire damper, etc., and can receive the action response signal of the equipment....
It is mainly used to connect fire-protection linkage equipment that needs to be controlled by fire alarm control panel, such as smoke exhaust valve, air supply valve, fire damper, etc., and can receive the action response signal of the equipment....
Open installation applied for the module. Insert mode for installation between base and module. When installing, pull down the module, lead the wire through wiring hole, connect it with terminal and push the module onto the base. The mounting hole...
It is mainly used to connect fire-protection linkage equipment that needs to be controlled by fire alarm control panel, such as smoke exhaust valve, air supply valve, fire damper, etc., and can receive the action response signal of the equipment....
TCMK5261 Addressable Single Input Module is used to receive normally open or normally closed swtich signals input by the fire linkage equipment, and transmit linkage information back to the fire alarm control panel (linkage). ▪LPCB CERTIFIED ▪ Input...
1. Base of the detector is shown below. There are 2 conductor pieces with terminals on the base. Detector' 5 loop should be respectively connected with
two terminals (non-polarized) After the base is fixed firmly, rotate the bottom of detector and...
LPCB FIRE ALARM SYSTEM TCMK5260 Addressable Loop Isolator Polarized connection with peripheral devices and no need to transfer connection of input and output. Delayed power supply to output terminal devices will avoid over load or strong transient...
* Conversion Between manual operation mode and automatic operation mode * Installed at the entrance of the protected area * In manual state,systems will not linkage
* In automatic state,systems will linkage * Configurable with JB-QB-QTC5015 Gas...
TCDK-1A11 Single Single-phase AC Voltage and Current Sensor
* Input current: rated value AC5A, setting range (0~8A)
* Input voltage: rated value AC220V, setting range (0~280V) TCDK-1A31 Single Three-phase Three-wire AC Voltage and Current Sensor
*...