Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
NAJ2311 Fire Alarm Power Supply
Model No:NAJ2311
Voltage:AC187-242V;50HZ±1% Battery:DC21V-DC28V Rated Output:Voltage:DC27V; Current:10A; Power:270W Operating Environment:Temperature: 0°C~+40°C; Relative Humidity: ≤95%, non-condensing Battery Dimension:150mm×98mm×95mm; 3.3KG Approval:CCCF...
JB-TB-TC5120 Linkage Automatic Fire Alarm Control Panel
Model No:JB-TB-TC5120
JB-TB-TC5120Intelligent Fire Alarm Control Panel-tiancheng(TC) The control panel can be used with all kinds of intelligent fire detectors, input modules, output modules, I/O modules, sounder strobe, fire repeater etc. Forming an alarm linkage...
JB-QB-TC5160 Automatic Fire Alarm Control Panel Linkage
Model No:JB-QB-TC5160
JB-QB-TC5160 Intelligent Fire Alarm Control Panel The control panel can be used with all kinds of intelligent fire detectors, input modules, output modules, I/O modules, sounder strobe, fire repeater etc. Forming an alarm linkage integrated control...
TCFS5089 Fire Repeater Display Panel
Model No:TCFS5089
It is used to display the fire location and related information of a certain floor or fire zone, and at the same time send out an sounder strobe alarm signals to inform people in nearby areas. * Display fire alarm position and information for...
TC5012/TC5012A Loop Control Panel
Model No:TC5012/TC5012A
Voltage:DC20V-DC28V Capacity:64/128Points Operating Environment:Temperature: 0°C~+40°C; Relative Humidity: ≤95%, non-condensing Dimension:482mm×88.5mm (64Points); 482mm×177.3mm (128Points) Working Mode:Integrated with...
JB-TG-TC5000 Intelligent Fire Alarm Control Panel
Model No:JB-TG-TC5000
The control panel can be used with all kinds of intelligent fire detectors, input modules, output modules, I/O modules, sounder strobe, fire repeater etc. Forming an alarm linkage integrated control panel, which is the best choice for fire...
TCSG5267 Addressable Sounder Strobe Two Bus System
Model No:TCSG5267
A kind of audio and visual alarm device used to warn people in field when fire occurs; * Non-polarized two-wire built-in microprocessor,with intelligent fuzzy judgment ability * Electronically coding * Equipped with self-diagnosis function to ensure...
TCMK5268 Addressable Single I/O Module Loop Powered
Model No:TCMK5268
It is mainly used to connect fire-protection linkage equipment that needs to be controlled by fire alarm control panel, such as smoke exhaust valve, air supply valve, fire damper, etc., and can receive the action response signal of the equipment....
TCSG5230R Addressable Sounder Strobe Loop Powered
Model No:TCSG5230R
Voltage:DC24V (16V~28V) Current:Standby Current: ≤0.4mA; Action Current: ≤5mA Operating Environment:Temperature: -10°C~+50°C;Relative Humidity: ≤95%(40±2°C) Sound Level:75dB~115dB (A weighted) Dimension:φ101mm×51mm Approval:CCCF/GOST Appearance: The...
TCSG5230 Four-wired Addressable Sounder Strobe
Model No:TCSG5230
Voltage:Loop: DC24V (16V~28V); Power: DC24V(18V-28V) Standby Current:Loop: ≤0.4mA; Power: 0.5mA Action Current:Loop: ≤1.2mA; Power: ≤15mA Operating Environment:Temperature: -10°C~+50°C;Relative Humidity: ≤95%(40±2°C) Sound Level:75dB~115dB (A...
TCSG5228F Conventional Sounder Strobe
Model No:TCSG5228F
TCSG5228F Conventional Sounder Strobe adopts 2 wires (24V power). It is mainly installed in public places. It generates a kind of optical and visual alarm used to warn people in field when fire occurs. With plug-in structure, reliable performance,...
TCMK5217 Interposing Relay Module
Model No:TCMK5217
Voltage Loop: DC24V (20V~28V) Current Standby Current:≤4.5mA; Action Current: <45mA Operating Environment Temperature: -10°C~+559C;Relative Humidity:≤95%, non-condensing Dimension (Lx WxH) 86mmx 38mm x86mm (with base) Working Mode Match with...
TCMK5223 Addressable Single I/O Module Loop Powered
Model No:TCMK5223
It is mainly used to connect fire-protection linkage equipment that needs to be controlled by fire alarm control panel, such as smoke exhaust valve, air supply valve, fire damper, etc., and can receive the action response signal of the equipment....
TCMK5216 Automatic Fire Alarm Output Module
Model No:TCMK5216
1. Base of the detector is shown below. There are 2 conductor pieces with terminals on the base. Detector' 5 loop should be respectively connected with two terminals (non-polarized) After the base is fixed firmly, rotate the bottom of detector and...
Model No:TCXH5215
TCXH5215 Addressable Fire Hydrant Button (the button) is installed in public places. When there is a fire, pressing the frangible element on the button can send startup signal to the fire alarm control panel and fire pump is activated. After...
J-SAP-TCSB5214H Digital Manual Call Point with Jack
Model No:J-SAP-TCSB5214H
J-SAP-TCSB5214H Digital Manual Call Point (With Jack) (MCP) is installed in public places. The MCP contains a phone jack. And when there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel. After...
TCMK5213 Addressable Single I/O Module
Model No:TCMK5213
It is mainly used to connect fire-protection linkage equipment that needs to be controlled by fire alarm control panel, such as smoke exhaust valve, air supply valve, fire damper, etc., and can receive the action response signal of the equipment....
TCMK5211 Addressable Single Input Module
Model No:TCMK5211
The input module is used to receive normally open or normally closed switch signals input by the fire linkage equipment, and transmit linkage information back to the fire alarm control panel (linkage). Voltage:Loop : DC24V(16V~28V) Current:Standby...
JTY-GD-TC901 Independent Photoelectric Smoke Detector
Model No:JTY-GD-TC901
The independent photoelectric smoke detector alarm uses special chip and advanced optical maze to detect smoke * Suitable for small houses or offices * 9V alkaline battery and carbon-zinc battery * Power saving and reliable work * Low rate of false...
TCBM5023 Handheld Encoder Fire Alarm Programmer
Model No:TCBM5023
In the contact encoding method, the device to be encoded can be encoded only by leaning on the stylus protruding from the encoder, which simplifies the encoding steps, shortens the encoding time and reduces the work intensity. The encoder can...
JB-TB-TC5109 Intelligent Fire Alarm Control Panel
Model No:JB-TB-TC5109
JB-TB-TC5109 Intelligent Fire Alarm control panel is a new generation of alarm control panel that is designed and developed by our company through researching the fire-fighting market demand and summarizing the fire engineering experience for many...
TCSG5266 Addressable Sounder Strobe
Model No:TCSG5266
General TCSG5266 Addressable Sounder Strobe adopts four wires, connecting to the fire alarm control panel, mainly installed in public places. It generates a kind of optical and visual alarm used to warn people in field when fire occurs. The built-in...
TCMK5263 Addressable Single I/O Module
Model No:TCMK5263
Open installation applied for the module. Insert mode for installation between base and module. When installing, pull down the module, lead the wire through wiring hole, connect it with terminal and push the module onto the base. The mounting hole...
TCFH-592B Fire Door Monitoring Interface
Model No:TCFH-592B
* Monitor double door normally closed fire door * The circuit part and the wiring bottom case are plugged in for reliable contact and easy construction * The address code is electronically encoded and can be written in advance by the electronic...
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.