J-SAP-TCSB5214H Digital Manual Call Point with Jack
Get Latest PricePayment Type: | L/C,T/T,D/P,D/A,Paypal,Money Gram,Western Union |
Incoterm: | FOB,CFR,CIF,EXW,FAS,FCA,CPT,CIP |
Transportation: | Ocean |
Port: | Dalian |
Payment Type: | L/C,T/T,D/P,D/A,Paypal,Money Gram,Western Union |
Incoterm: | FOB,CFR,CIF,EXW,FAS,FCA,CPT,CIP |
Transportation: | Ocean |
Port: | Dalian |
Model No.: J-SAP-TCSB5214H
Place Of Origin: China
Voltage: Loop : DC24V(16V-28V)
Current: Standby Current:≤0.2mA;Alarm Current: <0.8mA
Operating Environment: Temperature: -10°C~+559C;Relative Humidity:≤95%, non-condensing
Dimension (LxWxH): 95mmx44mmx95mm (with base)
Approval: CCCF
Selling Units | : | Others |
J-SAP-TCSB5214H Digital Manual Call Point (With Jack) (MCP) is installed in public places. The MCP contains a phone jack. And when there is a fire, pressing the frangible element on this MCP can send fire signal to Fire Alarm Control Panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound. Insert the Fire Telephone handle into the phone jack, and then communicate the fire telephone panel.
Features
1.Plug-in structure. Simple and convenient installation. Alarm by pressing, reset by a special key.
2.Pressing the frangible element and it can provide independent output contact through the MCP. And it can directly control other peripheral devices.
3.Microprocessor processes signal and digital signal communicates the Fire Alarm control panel. Stable and reliable work, good ability to inhibit electromagnetic interference.
4.Electronically addressed. The address can be modified in field. Easy and reliable for commissioning.
Technical Specifications
1.Operating voltage
Signal bus voltage: loop 24V
2.Operating current
Standby current: ≤ 0.2mA
Alarm current: ≤ 0.8mA
3.Type of initiating part: Reusable
4.0Initiating mode: Pressing the frangible element manually
5.Resuming mode: Manually resumed by a special key
6.Indicator
Running/fire LED: Red. Flashes every 3s when polling. Illuminates after alarming.
Fire telephone: Red. Flashes every 5s.
7.Programming mode
Electronically addressed (address range: one address within 1~255).
8.Wiring
Non-polarized signal two-wire
9.Operating environment
Class: indoor
Temperature: -10°C~+55°C
Relative Humidity: ≤95%, non-condensing
10.Dimension
Diameter: 90mm×90mm×42 mm (with base)
11.Material and color of enclosure: ABS; red
12.Weight: about 120g(with base)
13.Mounting hole distance: 60mm
14.Standard: GB 19880-2005
Appearance: The control panel adopts Akzo anti-corrosion coating. No pun-gent smell, anti-static electricity, non-toxic harm, non-pollution, no waste. The cabinet is made of stainless steel, which is not easy to deform and high-end and elegance
The Control Panel Is Equipped With A Fire Alarm And A Fault Output Port. The Output Of 24V In Case Of Fire Al Arm And Fault Effectively Provides A Convenient Way For External Device
Power Box: Equipped With Main Power Supply Detec-Tion Function. Easily Achieved Switching Between The Main And Standby Power. Insurance Of Its Own Can Provide Protection To The Control Panel When The External Current Is Too High
Standby Battery: 12V/12Ah Battery *2, Work For 12 Hours Without Main Power, Work For 3 Hours Without Main Power And Alarm In The Loop. And The Battery Has Its Own Charging Function. Con-Trol Panel Is Exquisite And Beautiful.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.